Pup Joint
Pup Joint Is A Special Type Of Oil Casing, We Can Understand It As A Short Length Of Oil Casing.
In An Oil Well Project, When Most Of The Tubing Is Laid In And Only A Few Meters Are Needed At The End, It Is Necessary To Use The Short Connection At This Time.
Generally Speaking, The Length Of The Short Connection Is 3 Feet, 6 Feet, 9 Feet, And 12 Feet. Its Buckle Type And The Petroleum Casing Can Be Consistent With Each Other, Often Purchasing A Batch Of Petroleum Casing Needs To Be Equipped With Some Short Pup Joint.
It Is A Flexible Product In Oil Exploration.
Recommended Products By Balingsteel
Casing Pup Joints
Balingsteel Is a High-Quality Supplier of Casing Pup Joints Same as Tenaris, Our Products Are Exported All over the World. For Your Customized Casing Pup Joints Size, We Can Provide the Following Specifications:
- OD: 4-1/2 inch To 30 inch
- Lengths: 1 ft, 2 ft, 3 ft, 4 ft, 6 ft, 8 ft, 9 ft,10 ft, 12 ft,15ft,18ft,21ft,24ft,27ft,30ft,33ft
- Material Grades: H40, J55, K55, N80, L80 T95, C110, P110
- Ends Connections: SC, EUE, LC, BC, BTC, VAM TOP and Other Premium Connections
Tubing Pup Joints
Balingsteel Is Also a High-Quality Supplier of Tubing Pup Joints, We Also Provide You with the Following Tubing Pup Joints Specifications:
- OD: 2-3/8″ To 4-1/2″
- Lengths: 1 ft, 2 ft, 3 ft, 4 ft, 6 ft, 8 ft, 9 ft,10 ft, 12 ft,15ft,18ft,21ft,24ft,27ft,30ft,33ft
- Material Grades: H40, J55, K55, N80, L80 T95, C110, P110
- Ends Connections: EUE, UE and Other Premium Connections
Data Sheet
- Chemical Composition and Mechanical Properties
- Range Lengths
- Flattening Tests
Chemical Composition and Mechanical Properties for Pup Joint
Grade | Type | C | Mn | Mo | Cr | Ni | Cu | P | S | Si | ||||
min | max | min | max | min | max | min | max | max | max | max | max | max | ||
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 |
H40 | — | — | — | — | — | — | — | — | — | — | — | 0.030 | 0.030 | — |
J55 | — | — | — | — | — | — | — | — | — | — | — | 0.030 | 0.030 | — |
K55 | — | — | — | — | — | — | — | — | — | — | — | 0.030 | 0.030 | — |
N80 | 1 | — | — | — | — | — | — | — | — | — | — | 0.030 | 0.030 | — |
N80 | Q | — | — | — | — | — | — | — | — | — | — | 0.030 | 0.030 | — |
R95 | — | — | 0.45 c | — | 1.90 | — | — | — | — | — | — | 0.030 | 0.030 | 0.45 |
L80 | 1 | — | 0.43 a | — | 1.90 | — | — | — | — | 0.25 | 0.35 | 0.030 | 0.030 | 0.45 |
L80 | 9Cr | — | 0.15 | 0.30 | 0.60 | 0.90 | 1.10 | 8.00 | 10.0 | 0.50 | 0.25 | 0.020 | 0.010 | 1.00 |
L80 | 13Cr | 0.15 | 0.22 | 0.25 | 1.00 | — | — | 12.0 | 14.0 | 0.50 | 0.25 | 0.020 | 0.010 | 1.00 |
C90 | 1 | — | 0.35 | — | 1.20 | 0.25 b | 0.85 | — | 1.50 | 0.99 | — | 0.020 | 0.010 | — |
T95 | 1 | — | 0.35 | — | 1.20 | 0.25 d | 0.85 | 0.40 | 1.50 | 0.99 | — | 0.020 | 0.010 | — |
C110 | — | — | 0.35 | — | 1.20 | 0.25 | 1.00 | 0.40 | 1.50 | 0.99 | — | 0.020 | 0.005 | — |
P110 | e | — | — | — | — | — | — | — | — | — | — | 0.030 e | 0.030 e | — |
Q125 | 1 | — | 0.35 | 1.35 | — | 0.85 | — | 1.50 | 0.99 | — | 0.020 | 0.010 | — |
Grade | Type | Total Elongation Under Load % |
Yield Strength MPa |
Tensile Strength | Hardness a,c max |
Specified Wall Thickness |
Allowable Hardness Variation b |
||
min | max | min MPa | HRC | HBW | mm | HRC | |||
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 |
H40 | — | 0.5 | 276 | 552 | 414 | — | — | — | — |
J55 | — | 0.5 | 379 | 552 | 517 | — | — | — | — |
K55 | — | 0.5 | 379 | 552 | 655 | — | — | — | — |
N80 N80 |
1 Q |
0.5 0.5 |
552 552 |
758 758 |
689 689 |
—
— |
—
— |
—
— |
—
— |
R95 | — | 0.5 | 655 | 758 | 724 | — | — | — | — |
L80 L80 L80 |
1 9Cr 13Cr |
0.5 0.5 0.5 |
552 552 552 |
655 655 655 |
655 655 655 |
23.0 23.0 23.0 |
241 241 241 |
—
— — |
—
— — |
C90 | 1 | 0.5 | 621 | 724 | 689 | 25.4 | 255 | ≤12.70 12.71 to 19.04 19.05 to 25.39 ≥ 25.40 |
3.0 4.0 5.0 6.0 |
T95 | 1 | 0.5 | 655 | 758 | 724 | 25.4 | 255 | ≤12.70 12.71 to 19.04 19.05 to 25.39 ≥ 25.40 |
3.0 4.0 5.0 6.0 |
C110 | — | 0.7 | 758 | 828 | 793 | 30.0 | 286 | ≤12.70 12.71 to 19.04 19.05 to 25.39 ≥ 25.40 |
3.0 4.0 5.0 6.0 |
P110 | — | 0.6 | 758 | 965 | 862 | — | — | — | — |
Q125 | 1 | 0.65 | 862 | 1034 | 931 | b | — | ≤12.70 12.71 to 19.04 ≥19.05 |
3.0 4.0 5.0 |
Range Lengths
Range 1 | Range 2 | Range 3 | |||||
CASING (PE/T and C/SF) Total range length, inclusive Permissible variation, max a |
4.88 to 7.62 1.83 |
7.62 to 10.36 1.52 |
10.36 to 14.63 1.83 |
||||
TUBING AND CASING USED AS TUBING (PE/T and C/SF) Total range length, inclusive Permissible variation, max a |
6.10 to 7.32 b 0.61 |
8.53 to 9.75 c 0.61 |
11.58 to 12.80 d 0.61 |
||||
INTEGRAL TUBING CONNECTIONS (including IJ/PE and IJ/SF) Total range length, inclusive Permissible variation, max a |
6.10 to 7.92 e 0.61 |
8.53 to 10.36 0.61 |
11.58 to 13.72 0.61 |
||||
PUP JOINTS | Lengths: 0.61; 0.91; 1.22; 1.83; 2.44; 3.05 and 3.66 e Tolerance: ±0.076 |
||||||
a.Length variation applies to rail car shipment to the point of use and does not apply to order items of less than 18,144 kg of pipe. b.By agreement between purchaser and manufacturer, the maximum length may be increased to 8.57 m. c.By agreement between purchaser and manufacturer, the maximum length may be increased to 10.76 m. d.By agreement between purchaser and manufacturer, the maximum length may be increased to 13.72 m. e.0.61 m pup joints may be furnished up to 0.91 m long by agreement between purchaser and manufacturer, and lengths other than those listed may be furnished by agreement between purchaser and manufacturer. |
Flattening Tests
Casing and Tubing | |||||
Grade | Type of Heat Treatment | Number of Tests | |||
1 | 2 | 3 | 4 | ||
H40, J55, K55, N80 (all types), L80 Type 1, R95, P110 |
Non-full-body | As described in footnote a | |||
Full-body, full- length |
≤ Label 1: 41/2 | Same as non-full-body heat-treated or 1 per lot of 100 lengths or less |
|||
> Label 1: 41/2 b | Same as non-full-body heat-treated or 1 per lot of 20 lengths or less |
||||
Q125 | All | 1 on each end of each length of pipe [see K.6 (SR 11)] | |||
Pup Joints | |||||
Grade | Type of Heat Treatment | Maximum Number of Pieces in a Lot | Number of Tests | ||
per Lot | per Heat | ||||
1 | 2 | 3 | 4 | 5 | 6 |
H40, J55, K55, N80 (all types), L80 Type 1, R95, P110 |
Treated after cutting to length |
Batch heat-treated | 100 pup joints | 1 | 1 |
Continuously heat- treated |
— | ||||
Treated before cutting to length |
≤ Label 1: 41/2 | 200 lengths | |||
> Label 1: 41/2 b | 100 lengths | ||||
Q125 | All | 1 on each end of each length of pipe |
|||
a.The leading end of the first pipe of each coil shall have two test specimens flattened: one in the 90° position and one in the 0° position;Two test specimens shall be flattened from an intermediate pipe of each coil: one in the 90° position and one in the 0° position; The trailing end of the last pipe of each coil shall have two test specimens flattened: one in the 90° position and one in the 0° position;When a weld stop condition occurs during production of a multiple length, flattening tests with the weld at the 90° position and 0° position shall be made from the crop end resulting from each side of the weld stop, and may be substituted for the intermediate flattening tests; 90° position: the weld is positioned at 3 o’clock or at 9 o’clock; 0° position: the weld is positioned at 6 o’clock or at 12 o’clock. b Includes casing used as tubing. |
- Casing Pup Joints:OD: 4-1/2″ To 30″
- Tubing Pup Joints:OD: 2-3/8″ To 4-1/2″
Usually, We Offer 1 ft, 2 ft, 3 ft, 4 ft, 6 ft, 8 ft, 9 ft,10 ft, 12 ft,15 ft,18 ft,21 ft,24 ft,27 ft,30 ft,33 ft Or Customized Length.
Suggested 7304291000,7304199000.We Can Discuss with You to Confirm the Final HS Code.